Ticket #527 (closed: fixed)

Opened 16 years ago

Last modified 16 years ago

SS not resetting when resetting F's

Reported by: carieh Owned by: administrator
Priority: normal Milestone: Ecopath 6: build 6.0.7
Component: Ecosim Version:
Severity: minor Keywords:
Cc:

Description

-open ecosim, apply a time series (note the SS value)
-apply a forcing function to a group (note the difference in SS vlaues) you may have to make a large FF, and just so you know I chose a seasonal one and applied to a top predator (to have significant effects)
-now remove the FF and note the SS value.
-Intuitively I would assume that the SS value would return back to the original value if I have undone (reset) the FF and have also clicked reset all in the run ecosim interface.

Perhaps I am missing something about how this works, let me know if this is not an issue

Change History

comment:1 Changed 16 years ago by administrator

related to #453

comment:2 Changed 16 years ago by jeroens

Joe, is this related to issue 459?

comment:3 Changed 16 years ago by joeb

Hi Carie
This seems to be work now on the version that I have. I tested it on a couple of databases. I've recently fix a bug that was related to the loading of Timeseries and calculation of SS which may have caused this issue to go away. If this is still an issue for you then send me the database that caused the problem and I'll take a look at it.

thanks joe

Note: See TracTickets for help on using tickets.