Description

If you try to build .. (generic 37 for example) in Ewe 6, the level position of each group in the flow diagram (built with EwE5.0) will be different than the data results in the table basic estimates. Maybe is a problem of the software between the flow diagram EwE 5 and the reading of the data from EwE6.

Change History

comment:1 Changed 13 years ago by jeroens

Hector is using a system with commas for decimal separators

comment:2 Changed 13 years ago by jeroens

Test 1: generating a flow diagram in EwE5 and EwE6 on a US system yields identical results

comment:3 Changed 13 years ago by jeroens

Test 2: generating a flow diagram in EwE5 and EwE6 on a decimal comma system yields identical results, and results identical to test 1. The plot thickens

comment:4 Changed 13 years ago by jeroens

  • Status changed from new to closed
  • Type changed from not assessed to assessed
  • Resolution set to fixed

Negative numbers passed to the flow diagram messed up the diagram data layout