Ticket #358 (closed: fixed)
Run Ecosim: Reset All
Reported by: | robynf | Owned by: | administrator |
---|---|---|---|
Priority: | normal | Milestone: | Ecopath 6: build 6.0.7 |
Component: | Ecosim | Version: | |
Severity: | major | Keywords: | |
Cc: |
Description
The Reset All button on the Run Ecosim form seems not to work. e.g. I set to 0 and the results change. But there is no change after that after I press Reset All.
The Set to value ... dialogue box also doesn't work. In the Georgia Strait model I tried to use it to reset Fs by typing 1,1,1,1. The results changed but not back to the original values.
Also, the y-axis of the F sketch pad showed really high values (x1110) but the results didn't appear to reflect such high Fs.
Change History
comment:2 Changed 15 years ago by carieh
version 6.0.3.11
All fleets are not updating (pick a smaller model)
-go to run Ecosim
-Draw a shape for every group
-run ecosim
-reset all
-all but the individual fleet will reset to original value
I was using the Ocean Test model (and the First Fleet was not updating)
Reset all issue has been fixed earlier, will appear after build 6.0.3.7
The high values as result of the set dialog were caused by misinterpretation of comma's in the entered values. Note that this dialog only accepts SPACE separated values, not COMMA separated values!
Fixed after build 6.0.3.7